Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

RS tootekood: 410-517Bränd: ParkerTootja Part nr.: PRT-A10
brand-logo

Tehnilised dokumendid

Spetsifikatsioonid:

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Toote üksikasjad

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Teid võib huvitada

Lao andmed ajutiselt ei ole saadaval.

Palun kontrollige hiljem uuesti.

Lao andmed ajutiselt ei ole saadaval.

€ 309,00

tk (ilma käibemaksuta)

€ 376,98

tk (koos käibemaksuga)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

€ 309,00

tk (ilma käibemaksuta)

€ 376,98

tk (koos käibemaksuga)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
Lao andmed ajutiselt ei ole saadaval.

Osta lahtiselt

kogusÜhikuhind
1 - 4€ 309,00
5+€ 297,00
Teid võib huvitada

Tehnilised dokumendid

Spetsifikatsioonid:

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Toote üksikasjad

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Teid võib huvitada