ETA Thermal Circuit Breaker / Switch - 3120 2 Pole Snap In, 10A Current Rating

RS tootekood: 739-6872Bränd: ETATootja Part nr.: 3120-F521-H7T1-W01D-10A-U0000M
brand-logo

Tehnilised dokumendid

Spetsifikatsioonid:

Brand

ETA

Current Rating

10A

Number of Poles

2

Width

25mm

Series

3120

Reset Actuator Type

Rocker

Mounting Style

Snap In

Toote üksikasjad

CBE, 2 Pole Sensing, 2 Pole Switching, 3120 Series

IEC Classification S/TO (with modules, S/TM). This range of 2 pole sensing thermal switch and circuit breaker offer enhance protection over single pole devices with the added benefit of not being 'polarity' sensitive for wiring purposes. Basic tripping time at 2xIN, 20-30 second. These units may also be used with the magnetic conversion module in this range,to convert the breaker to a thermal/magnetic type, for closer protection against short circuits. Circuit protection designed for equipment, sub-systems and components.

Approvals

UL, CSA, VDE, BV

Thermal Magnetic Convertible

All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).

Lao andmed ajutiselt ei ole saadaval.

€ 53,00

€ 53,00 tk (ilma käibemaksuta)

€ 64,66

€ 64,66 tk (koos käibemaksuga)

ETA Thermal Circuit Breaker / Switch - 3120 2 Pole Snap In, 10A Current Rating

€ 53,00

€ 53,00 tk (ilma käibemaksuta)

€ 64,66

€ 64,66 tk (koos käibemaksuga)

ETA Thermal Circuit Breaker / Switch - 3120 2 Pole Snap In, 10A Current Rating
Lao andmed ajutiselt ei ole saadaval.

Lao andmed ajutiselt ei ole saadaval.

Palun kontrollige hiljem uuesti.

kogusÜhikuhind
1 - 9€ 53,00
10 - 24€ 52,00
25 - 49€ 48,60
50 - 99€ 47,30
100+€ 46,00

Tehnilised dokumendid

Spetsifikatsioonid:

Brand

ETA

Current Rating

10A

Number of Poles

2

Width

25mm

Series

3120

Reset Actuator Type

Rocker

Mounting Style

Snap In

Toote üksikasjad

CBE, 2 Pole Sensing, 2 Pole Switching, 3120 Series

IEC Classification S/TO (with modules, S/TM). This range of 2 pole sensing thermal switch and circuit breaker offer enhance protection over single pole devices with the added benefit of not being 'polarity' sensitive for wiring purposes. Basic tripping time at 2xIN, 20-30 second. These units may also be used with the magnetic conversion module in this range,to convert the breaker to a thermal/magnetic type, for closer protection against short circuits. Circuit protection designed for equipment, sub-systems and components.

Approvals

UL, CSA, VDE, BV

Thermal Magnetic Convertible

All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).