Technical Document
Specifications
Brand
ABBCoil Voltage
240 V
Product Type
Contactor
Number of Poles
3
Contact Voltage
690V
Contact Current
9A
Series
VB6
Power Rating
4kW
Mount Type
DIN Rail
Function
Reversing
Normal State Configuration
3 NO
Number of Auxiliary Contacts
1
Auxiliary Contact Configuration
1 NO
Terminal Type
Screw
Control Circuit Voltage Uc
240 V
Operational Current Ie
9A
Minimum Operating Temperature
-20°C
Contactor Application
Reversing
Maximum Operating Temperature
55°C
Width
96.5 mm
Depth
46.7mm
Length
46.7mm
Standards/Approvals
CCC, CE, CSA, cULus, RoHS, UKCA, UL
Pole and Throw Configuration
3
Country of Origin
Germany
Product details
VB6/VB7 - Compact Rreversing Contactors
The mechanical lock between the two contactors prevents one of the contactors from switching on, as long as the other is still switched on and vice versa.
Switching over reversing contactors too quickly poses the risk of a phase short circuit.
This is the case if the arc of the contactor switching off has not yet extinguished and the contacts of the contactor switching on are already closed.
To avoid this risk, the two contactor coils must be switched to idle for a minimum of 50 ms during the switchover process and electrically locked against each other.
Stock information temporarily unavailable.
€ 90.35
€ 90.35 Each (Exc. Vat)
€ 112.03
€ 112.03 Each (inc. VAT)
1
€ 90.35
€ 90.35 Each (Exc. Vat)
€ 112.03
€ 112.03 Each (inc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
ABBCoil Voltage
240 V
Product Type
Contactor
Number of Poles
3
Contact Voltage
690V
Contact Current
9A
Series
VB6
Power Rating
4kW
Mount Type
DIN Rail
Function
Reversing
Normal State Configuration
3 NO
Number of Auxiliary Contacts
1
Auxiliary Contact Configuration
1 NO
Terminal Type
Screw
Control Circuit Voltage Uc
240 V
Operational Current Ie
9A
Minimum Operating Temperature
-20°C
Contactor Application
Reversing
Maximum Operating Temperature
55°C
Width
96.5 mm
Depth
46.7mm
Length
46.7mm
Standards/Approvals
CCC, CE, CSA, cULus, RoHS, UKCA, UL
Pole and Throw Configuration
3
Country of Origin
Germany
Product details
VB6/VB7 - Compact Rreversing Contactors
The mechanical lock between the two contactors prevents one of the contactors from switching on, as long as the other is still switched on and vice versa.
Switching over reversing contactors too quickly poses the risk of a phase short circuit.
This is the case if the arc of the contactor switching off has not yet extinguished and the contacts of the contactor switching on are already closed.
To avoid this risk, the two contactor coils must be switched to idle for a minimum of 50 ms during the switchover process and electrically locked against each other.