Technical Document
Specifications
Brand
BlockProduct Type
PCB Transformer
Secondary Voltage
15 V ac
Primary Voltage
230 V ac
Number of Outputs
2
Length
51mm
Width
36 mm
Depth
43mm
Power
7.5VA
Weight
280g
Mount Type
Through Hole
PCB Transformer Current
0.25A
Winding Type
Single Primary, Dual Secondary
Efficiency
65%
Maximum Operating Temperature
40°C
Minimum Operating Frequency
50Hz
Standards/Approvals
VDE, UL
Maximum Operating Frequency
60Hz
Country of Origin
Germany
Product details
Transformers PCB Mount, Short Circuit Proof, VB & PT Series
230Va.c. 50 to 60Hz primary
Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval)
VB series (0.35 - 3.2VA) are inherently short circuit proof
PT series (4.5 - 22VA) are protected by internal PTC device
Compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
High efficiency and low temperature rise
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure boarding mounting on 4.5VA and above
Approvals
ENEC 10; UL recognised component
Standards
EN 61558
Stock information temporarily unavailable.
€ 30.60
€ 30.60 Each (Exc. Vat)
€ 37.94
€ 37.94 Each (inc. VAT)
1
€ 30.60
€ 30.60 Each (Exc. Vat)
€ 37.94
€ 37.94 Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 9 | € 30.60 |
| 10 - 24 | € 24.20 |
| 25 - 49 | € 23.00 |
| 50 - 99 | € 21.90 |
| 100+ | € 20.80 |
Technical Document
Specifications
Brand
BlockProduct Type
PCB Transformer
Secondary Voltage
15 V ac
Primary Voltage
230 V ac
Number of Outputs
2
Length
51mm
Width
36 mm
Depth
43mm
Power
7.5VA
Weight
280g
Mount Type
Through Hole
PCB Transformer Current
0.25A
Winding Type
Single Primary, Dual Secondary
Efficiency
65%
Maximum Operating Temperature
40°C
Minimum Operating Frequency
50Hz
Standards/Approvals
VDE, UL
Maximum Operating Frequency
60Hz
Country of Origin
Germany
Product details
Transformers PCB Mount, Short Circuit Proof, VB & PT Series
230Va.c. 50 to 60Hz primary
Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval)
VB series (0.35 - 3.2VA) are inherently short circuit proof
PT series (4.5 - 22VA) are protected by internal PTC device
Compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
High efficiency and low temperature rise
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure boarding mounting on 4.5VA and above
Approvals
ENEC 10; UL recognised component
Standards
EN 61558