Crouzet Voltage Monitoring Relay, 1 Phase, SPDT, 65 → 260V ac/dc, DIN Rail

RS tootekood: 262-211Bränd: CrouzetTootja Part nr.: 84872152
brand-logo
View all in Monitoring Relays

Tehnilised dokumendid

Spetsifikatsioonid:

Brand

Crouzet

Monitoring Application

Voltage

Electrical Phase

1

Voltage Sensing Range

65 → 260V ac/dc

Contact Configuration

SPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Time Delay

0.1 → 10s

Series

MUSF

Maximum Operating Temperature

+50°C

Dimensions

69 x 17.5 x 92.6mm

Maximum Voltage Sensed

260V ac/dc

Width

17.5mm

Height

92.6mm

Length

69mm

Minimum Voltage Sensed

65V ac/dc

Operating Temperature Range

+50°C

Minimum Operating Temperature

-20°C

Toote üksikasjad

Voltage Control Relay - C-Lynx

MUS and MUSF voltage control relays monitor single phase DC network voltages. These products monitor their own supply voltage. MUS relays allow the operator to choose between two operating modes: Under/overvoltage and with or without fault latching. An adjustable time delay, on threshold crossing, provides immunity from transient phenomena, thus preventing spurious triggering of the output relay.

Lao andmed ajutiselt ei ole saadaval.

Palun kontrollige hiljem uuesti.

Lao andmed ajutiselt ei ole saadaval.

€ 155,00

tk (ilma käibemaksuta)

€ 189,10

tk (koos käibemaksuga)

Crouzet Voltage Monitoring Relay, 1 Phase, SPDT, 65 → 260V ac/dc, DIN Rail

€ 155,00

tk (ilma käibemaksuta)

€ 189,10

tk (koos käibemaksuga)

Crouzet Voltage Monitoring Relay, 1 Phase, SPDT, 65 → 260V ac/dc, DIN Rail
Lao andmed ajutiselt ei ole saadaval.

Osta lahtiselt

kogusÜhikuhind
1 - 4€ 155,00
5 - 9€ 148,00
10 - 24€ 140,00
25 - 49€ 132,00
50+€ 124,00

Tehnilised dokumendid

Spetsifikatsioonid:

Brand

Crouzet

Monitoring Application

Voltage

Electrical Phase

1

Voltage Sensing Range

65 → 260V ac/dc

Contact Configuration

SPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Time Delay

0.1 → 10s

Series

MUSF

Maximum Operating Temperature

+50°C

Dimensions

69 x 17.5 x 92.6mm

Maximum Voltage Sensed

260V ac/dc

Width

17.5mm

Height

92.6mm

Length

69mm

Minimum Voltage Sensed

65V ac/dc

Operating Temperature Range

+50°C

Minimum Operating Temperature

-20°C

Toote üksikasjad

Voltage Control Relay - C-Lynx

MUS and MUSF voltage control relays monitor single phase DC network voltages. These products monitor their own supply voltage. MUS relays allow the operator to choose between two operating modes: Under/overvoltage and with or without fault latching. An adjustable time delay, on threshold crossing, provides immunity from transient phenomena, thus preventing spurious triggering of the output relay.