Technical Document
Specifications
Brand
Texas InstrumentsProduct Type
Voltage Reference
Package Type
SOT-23
Reference Voltage
36V
Reference Type
Adjustable
Output Voltage
2.5/36 V
Initial Accuracy
±0.5 %
Mount Type
Surface
Temperature Coefficient
92 ppm/°C
Topology
Shunt
Output Current
100mA
Maximum Input Voltage
37V
Pin Count
3
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
125°C
Width
1.3 mm
Height
1mm
Length
2.92mm
Standards/Approvals
No
Series
TL431
Minimum Input Voltage
2.48V
Output Type
Adjustable
Automotive Standard
No
Product details
Shunt Voltage Reference, Adjustable, TL Series
Voltage References, Texas Instruments
Precison Fixed and Adjustable Voltage Reference ICs utilsing series, shunt or series/shunt topologies and available in both through-hole and surface mount packages. Voltage References are available with initial accuracies of ±0.02 to ±2%.
Stock information temporarily unavailable.
€ 172.75
€ 0.691 Each (On a Reel of 250) (Exc. Vat)
€ 214.21
€ 0.857 Each (On a Reel of 250) (inc. VAT)
250
€ 172.75
€ 0.691 Each (On a Reel of 250) (Exc. Vat)
€ 214.21
€ 0.857 Each (On a Reel of 250) (inc. VAT)
Stock information temporarily unavailable.
250
Technical Document
Specifications
Brand
Texas InstrumentsProduct Type
Voltage Reference
Package Type
SOT-23
Reference Voltage
36V
Reference Type
Adjustable
Output Voltage
2.5/36 V
Initial Accuracy
±0.5 %
Mount Type
Surface
Temperature Coefficient
92 ppm/°C
Topology
Shunt
Output Current
100mA
Maximum Input Voltage
37V
Pin Count
3
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
125°C
Width
1.3 mm
Height
1mm
Length
2.92mm
Standards/Approvals
No
Series
TL431
Minimum Input Voltage
2.48V
Output Type
Adjustable
Automotive Standard
No
Product details
Shunt Voltage Reference, Adjustable, TL Series
Voltage References, Texas Instruments
Precison Fixed and Adjustable Voltage Reference ICs utilsing series, shunt or series/shunt topologies and available in both through-hole and surface mount packages. Voltage References are available with initial accuracies of ±0.02 to ±2%.