Tehnilised Dokumendid
Spetsifikatsioonid:
Brand
PR ElectronicsProduct Type
Pulse Isolator
Input Signal Type
Switch
Output Signal Type
Relay
Supply Voltage
19.2, 31.2V dc
Hazardous Area Certification
UL, Zone, DNV GL, EAC, ATEX, Zone 2, EU RO marine, FM, IECEx
Mount Type
DIN Rail
Terminal Type
Screw
Maximum Operating Temperature
60°C
Minimum Operating Temperature
-20°C
IP Rating
IP20
Standards/Approvals
Zone 2-DIV 2, FM, NE 21, DNV-GL / EU-RO marine, NE 43, IECEX, UL 61010 / 508, EAC, ATEX, NAMUR, Zone 2
Series
9200
Päritoluriik
Denmark
Toote üksikasjad
Single channel pulse isolator with N/C relay output
PR Electronics 9202B pulse isolator for transmission of signals to the safe area from NAMUR sensors and mechanical switches installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 9202B uses transformer and optical isolation techniques to provide 2.6 kV galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 9202B are not electrically connected to the output pulse. The 9202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 9202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 9202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.
The 9202B universal transmitters are programmable via the PR 4510 detachable display module (238-0641). The 4510 module allows the programming of the vast array of input and output parameters easily and safely. Together with advanced functions including 2 point calibration, process simulation and diagnostics.
With a simple menu and explanatory text the 4510 is extremely straightforward to navigate. Functions are clearly depicted on the 4 line LCD display even in low light conditions. Line 1 shows the input signal, line 2 shows the units, and line 3 shows analogue output or tag number. Line 4 shows the communication and relay status. In addition the 4510 features password protection. Programming access can be blocked by assigning a password which is conveniently saved in the 9202B transmitter. This ensures a high degree of protection is maintained and prevents any unauthorised modifications to the configuration.
Lao andmed ajutiselt ei ole saadaval.
€ 255,00
€ 255,00 tk (ilma käibemaksuta)
€ 316,20
€ 316,20 tk (koos käibemaksuga)
1
€ 255,00
€ 255,00 tk (ilma käibemaksuta)
€ 316,20
€ 316,20 tk (koos käibemaksuga)
Lao andmed ajutiselt ei ole saadaval.
1
Tehnilised Dokumendid
Spetsifikatsioonid:
Brand
PR ElectronicsProduct Type
Pulse Isolator
Input Signal Type
Switch
Output Signal Type
Relay
Supply Voltage
19.2, 31.2V dc
Hazardous Area Certification
UL, Zone, DNV GL, EAC, ATEX, Zone 2, EU RO marine, FM, IECEx
Mount Type
DIN Rail
Terminal Type
Screw
Maximum Operating Temperature
60°C
Minimum Operating Temperature
-20°C
IP Rating
IP20
Standards/Approvals
Zone 2-DIV 2, FM, NE 21, DNV-GL / EU-RO marine, NE 43, IECEX, UL 61010 / 508, EAC, ATEX, NAMUR, Zone 2
Series
9200
Päritoluriik
Denmark
Toote üksikasjad
Single channel pulse isolator with N/C relay output
PR Electronics 9202B pulse isolator for transmission of signals to the safe area from NAMUR sensors and mechanical switches installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 9202B uses transformer and optical isolation techniques to provide 2.6 kV galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 9202B are not electrically connected to the output pulse. The 9202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 9202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 9202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.
The 9202B universal transmitters are programmable via the PR 4510 detachable display module (238-0641). The 4510 module allows the programming of the vast array of input and output parameters easily and safely. Together with advanced functions including 2 point calibration, process simulation and diagnostics.
With a simple menu and explanatory text the 4510 is extremely straightforward to navigate. Functions are clearly depicted on the 4 line LCD display even in low light conditions. Line 1 shows the input signal, line 2 shows the units, and line 3 shows analogue output or tag number. Line 4 shows the communication and relay status. In addition the 4510 features password protection. Programming access can be blocked by assigning a password which is conveniently saved in the 9202B transmitter. This ensures a high degree of protection is maintained and prevents any unauthorised modifications to the configuration.